Intelligent fire inspection cabinet is a fixed fire-fighting special intelligent equipment independently researched and developed by the company. The products are designed and manufactured in strict accordance with the national performance requirements and experimental methods for fixed fire water supply equipment, and each performance has reached the leading level of domestic similar products.

Scope of application:

Hotel, bath center, community water supply and fire control, construction site water, water plant, farmland irrigation and other water systems.

 
1、 Manufacturing basis of digital intelligent fire inspection cabinet series:

Code for fire protection design of high rise civil buildings

Code for design of fire water supply system and hydrant system

Public safety industry standard of the people's Republic of China ga30.2-2002

Fire fighting linkage control system gb16806-2006

Code for construction and acceptance of electrical installation engineering

2、 The working principle of digital intelligent fire inspection cabinet is as follows:

 
3、 Composition of digital intelligent fire inspection cabinet system:

■ intelligent patrol actuator

■ inspection controller

■ inspection window

■ inspection software system

■ supporting electrical components

■ equipment box

4、 Performance of digital intelligent fire inspection cabinet

Accession The fire pump shall be inspected automatically at low frequency and low speed without pressure regularly;

Accession The starting power is small and will not impact the power grid;

Accession Do not pressurize the fire water supply network, and will not affect the safety of the network system;

Accession Prevent the occurrence of water pump rust and rust death and the dehumidification of motor, etc;

Accession When patrol inspection is carried out in the way of fire fighting, overpressure prevention device shall be set;

Accession Automatic patrol inspection of dual power supply system: check the normality of main and standby power supply;

Accession Patrol inspection of electrical control system;

Accession Patrol inspection for sewage pump of fire pump house: in case of no sewage discharge in the pump house for a long time, prevent the sewage pump from rusting and rusting, which can not be operated when necessary, causing a large amount of water in the pump house, damaging the fire-fighting equipment, and paralyzing the fire-fighting system;

Accession Electric valve inspection;

Accession The microcomputer intelligent inspection equipment has self inspection function;

Accession When in patrol inspection, receive the fire command and switch to the fire fighting working state in 0.5s;

Accession The inspection power consumption is very low, only about 1% of the rated power;

Accession Liquid level alarm function, automatic stop of low water level, automatic start of recovery water level, automatic alarm of abnormal water level;

Accession Image display, fault record, operation, fault content display, fault record is power down retention type, can query history record, and can store 20000 fault information;

Accession Automatic printing of fault information;

Accession Fault alarm: audible and visual alarm at the equipment site, alarm in the fire control room, telephone alarm, mobile phone voice, SMS alarm;

Accession RS485 standard interface and digital monitoring interface are reserved;

Accession It can be connected with the fire control center room for remote data transmission and remote control;

Accession Remote network fault diagnosis, data maintenance and function upgrading;

Accession The equipment adopts high-grade industrial control microcomputer to realize intelligent control and full-automatic operation. It has many memory functions, such as: the number and time of receiving fire alarm can be memorized).

Accession The cycle and time of each fire patrol inspection can be set on the site by the microcomputer panel, and the total number of inspections, the date of the last inspection and the date of the next inspection can be consulted.

Accession The fire pump is automatically started and supplemented according to the fire signal, and the standby pump is automatically put into operation in case of main pump failure.

Accession It can be linked with the active 220V, DC 24V or passive normally open signal of the fire control center, and equipped with the response feedback terminal.

Accession It has functions of manual, automatic and remote control of fire control center.

Accession With the communication interface of remote monitoring, it can communicate with the monitoring center, realize the central monitoring or management of the equipment, and remove the fault remote monitoring.